Stroke limiterIt allows to limit the plug run in opening phase, therefore it regulates the flow. Available on all versions. In spring return normally open version it can be used as an emergency control
| Control |
A mm. |
| DN 50 |
25,5 |
| DN 63 |
21,5 |
| DN 90 |
5,2 |
| DN 110 |
5,9 |
| Not available
with DN 40 head |
Emergency manual overrideIt allows to open the valve in emergency cases (lack of pilot fluid, machinery damaged, lack of piloting signal)
It is available on all normally closed valves.
| Control |
A mm. |
| DN 50 |
35,8 |
| DN 63 |
35,8 |
| DN 90 |
29,5 |
| DN 110 |
29,5 |
| Not available
with DN 40 head |
Limit switch boxThe control box to check the open/close positions with two mechanical limit switches is suitable for assembling on all the range of valves with actuators DN50 - DN63 - DN90 - DN110.
The terminals to connect the solenoid valve and the visual indicators provided with led are optional.
Level of protection: IP 65.
Room temperature: from –20° C to +70°C.
Access lead nr. 2 PG11.
Body material: polyamide (cap in Lexan/polycarbonate).
| Control |
A mm. |
| DN 50 |
52,1 |
| DN 63 |
47,5 |
| DN 90 |
37,7 |
| DN 110 |
29,5 |
Inductive limit switches NAMUR EExiaNominal voltage: 8 Vdc
Consumes: working 1mA; resting 3 mA
Working temperature: from –25°C to +100°C
| Configuration |
Code |
| 1 Limit switch at the top:
open valve |
KSIN9A0xx |
| 1 Limit switch at the
bottom: close valve |
KSIN9C0xx |
| 2 Limit switch open and
close valve |
KSIN920xx |
Proximity limit switchesNominal voltage: 10÷30 Vdc
Consumes: 15mA;
Working temperature: from –25°C to +70°C
| Configuration |
Code |
| 1 Limit switch at the top:
open valve |
KSI09A0xx |
| 1 Limit switch at the
bottom: close valve |
KSI09C0xx |
| 2 Limit switch open and
close valve |
KSI0920xx |
Mechanical limit switchesLimit switch at the top: open valve
Limit switch at the bottom: close valve
Max. capacity 5A 250 Vac;
1A 250 Vdc
| Configuration |
Code |
| 2 limit switch |
KSM0C20xx |
Control solenoid valvesElectro-pilot 3/2 for direct assembling.
Body and reel positionable at 360°.
Standard manual control.
Solenoid valve sets for selection between function
5/3 or 3/2, achievable by rotating the interconnecting
plate to 180°.
Room temperature: from –10°c to +50°C.
| Electro-pilot |
EP415024 |
EP415110 |
EP415220 |
EP412010 |
EP412024 |
| Voltage |
24Vac |
115Vac |
230Vac |
12Vdc |
24Vdc |
| Solenoid valve |
ER8188A2 |
ER8188A4 |
ER8188A5 |
ER8188C1 |
ER8188C2 |
|