Stroke limiter

It allows to limit the plug run in opening phase, therefore it regulates the flow. Available on all versions. In spring return normally open version it can be used as an emergency control

pag_62
Control A mm.
DN 50 25,5
DN 63 21,5
DN 90 5,2
DN 110 5,9
Not available with DN 40 head


Emergency manual override

It allows to open the valve in emergency cases (lack of pilot fluid, machinery damaged, lack of piloting signal)
It is available on all normally closed valves.

pag_63
Control A mm.
DN 50 35,8
DN 63 35,8
DN 90 29,5
DN 110 29,5
Not available with DN 40 head


Limit switch box

The control box to check the open/close positions with two mechanical limit switches is suitable for assembling on all the range of valves with actuators DN50 - DN63 - DN90 - DN110.
The terminals to connect the solenoid valve and the visual indicators provided with led are optional.
Level of protection: IP 65.
Room temperature: from –20° C to +70°C.
Access lead nr. 2 PG11.
Body material: polyamide (cap in Lexan/polycarbonate).


pag_64

Control A mm.
DN 50 52,1
DN 63 47,5
DN 90 37,7
DN 110 29,5


Inductive limit switches NAMUR EExia

Nominal voltage: 8 Vdc
Consumes: working 1mA; resting 3 mA
Working temperature: from –25°C to +100°C

pag_65
Configuration Code
1 Limit switch at the top: open valve KSIN9A0xx
1 Limit switch at the bottom: close valve KSIN9C0xx
2 Limit switch open and close valve KSIN920xx


Proximity limit switches

Nominal voltage: 10÷30 Vdc
Consumes: 15mA;
Working temperature: from –25°C to +70°C

pag_proxfinecorsa.gif
Configuration Code
1 Limit switch at the top: open valve KSI09A0xx
1 Limit switch at the bottom: close valve KSI09C0xx
2 Limit switch open and close valve KSI0920xx


Mechanical limit switches

Limit switch at the top: open valve
Limit switch at the bottom: close valve
Max. capacity 5A 250 Vac;
1A 250 Vdc

pag_1meccafinecorsa.gif
Configuration Code
2 limit switch KSM0C20xx


Control solenoid valves

Electro-pilot 3/2 for direct assembling.
Body and reel positionable at 360°.
Standard manual control.
Solenoid valve sets for selection between function
5/3 or 3/2, achievable by rotating the interconnecting
plate to 180°.
Room temperature: from –10°c to +50°C.


Electro-pilot EP415024 EP415110 EP415220 EP412010 EP412024
Voltage 24Vac 115Vac 230Vac 12Vdc 24Vdc
Solenoid valve ER8188A2 ER8188A4 ER8188A5 ER8188C1 ER8188C2

pag_68
pag_69

OMAL S.P.A. Via Ponte Nuovo, 11 - 25050 Rodengo Saiano (BS) ITALY - p.iva 00645720988 - tel. +390308900145 - fax +390308900423 omal@omal.it
Reg. Imp. BS N. 1661640175 - R.E.A. BS N. 258271 - Cod. Mecc. BS006939 - Capitale sociale € 500.000 i.v.